[FREE]Braindump2go 350-080 Exam Ref PDF Download (231-240)

CISCIO NEW UPDATED: New Updated 350-080 Exam Questions from Braindump2go 350-080 PDF Dumps and 350-080 VCE Dumps! Welcome to Download the Newest Braindump2go 350-080 VCE&PDF Dumps: http://www.braindump2go.com/350-080.html (394 Q&As)

Quick and Effective Cisco 350-080 Exam Preparation Options – Braindump2go new released 350-080 Exam Dumps Questions! Cisco Official 350-080 relevant practice tests are available for Instant downloading at Braindump2go! PDF and VCE Formates, easy to use and install! 100% Success Achievement Guaranteed!

Vendor: Cisco
Exam Code: 350-080
Exam Name: CCIE Data Center Written Exam

350-080 Dumps,350-080 Exam Dumps,350-080 Brainfump,350-080 Questions,350-080 VCE,350-080 PDF,350-080 Actual Test,350-080 Study Guide,350-080 Book,350-080 CCIE Data Center Written Exam,350-080 Test

QUESTION 231
Which two methods can be used in communications between the Cisco Nexus 1000V VEM and the VSM? (Choose two.)

A.    routed TCP traffic using HTTPS
B.    routed UDP traffic using port 4785
C.    routed UDP traffic using port 7845
D.    Layer 2 direct traffic using MAC addresses
E.    Layer 2 broadcast traffic
F.    routed TCP traffic using port 4785
G.    routed TCP traffic using port 7845

Answer: BD

QUESTION 232
Refer to the exhibit. An administrator is setting up the VSM and VEM in Layer 3 mode. The administrator adds a host to the distributed switch in VMware, but does not see the module join the VSM. Given the configuration in the exhibit, which three configuration items must be included in the configuration? (Choose three.)


A.    The vEthernet Port Profile parameter must be set to Capability I3control.
B.    The vEthernet Port Profile parameter must be set to VSM l3control.
C.    The Ethernet Port Profile parameter must be set to System VLAN 1400.
D.    The Ethernet Port Profile parameter must be set to VLAN 1400 in the allowed trunk.
E.    The Ethernet Port Profile parameter must be set to Capability l3control.
F.    The vEthernet Port Profile parameter must be set to Mode Trunk. G. The vEthernet Port Profile parameter must be set to VEM l3control.

Answer: ACD

QUESTION 233
Refer to the exhibit. An administrator is setting up the VSM and VEM in Layer 3 mode. The administrator adds a host to the distributed switch in VMware, but does not see the module join the VSM. Given the configuration in the exhibit, which configuration needs to be included?


A.    ip route 0.0.0.0 0.0.0.0 10.10.10.1
B.    vrf context control
ip route 0.0.0.0 0.0.0.0 10.10.10.1
C.    vrf context management
ip route 0.0.0.0 0.0.0.0 10.10.10.1
D.    ip route vrf management 0.0.0.0 0.0.0.0 10.10.10.1

Answer: A

QUESTION 234
Where can port profiles be created for the Cisco Nexus 1000V?

A.    on the VSM only
B.    on vCenter only
C.    on VSM and vCenter
D.    on VSM and VEM
E.    on VSM, VEM, and vCenter

Answer: A

QUESTION 235
Where can port profiles be applied to a virtual machine?

A.    on the VSM only
B.    on vCenter only
C.    on VSM and vCenter
D.    on VSM and VEM
E.    on VSM, VEM, and vCenter

Answer: B

QUESTION 236
The Cisco Nexus 1000V Series implementation has two main components. Which two components together make up the Cisco Nexus 1000V Series Switch? (Choose two.)

A.    virtual supervisor module
B.    virtual Ethernet module
C.    virtual machine NICs
D.    virtual machine kernel NICs

Answer: AB

QUESTION 237
Refer to the exhibit. A port profile is created in the VSM, but it is not seen in vCenter and cannot be assigned to a virtual machine. Given the configuration in the exhibit, which VSM command will resolve this issue?


A.    vmware port-group
B.    vmware port-active
C.    profile-active
D.    port-group active
E.    shutdown / no shutdown

Answer: A

QUESTION 238
Which two statements about dynamic port binding are true? (Choose two.)

A.    The port is connected when the VM is powered on and disconnected when the VM is powered off.
B.    The port is created when the VM is powered on and destroyed when the VM is powered off.
C.    The max-port limits are enforced.
D.    The max-port limits are not enforced.
E.    The port is always connected.

Answer: AC

QUESTION 239
Refer to the exhibit. The network administrator is adding a new Cisco Nexus 1000V Switch to vCenter, but does not see the new switch under the vCenter networking tab. The administrator issues the command that is shown in the exhibit on VSM to troubleshoot this problem. When the administrator attempts to fix the issue, the error that is shown in the exhibit is seen. Which option describes the most correct cause of this error?


A.    There is a missing control VLAN in the VSM configuration.
B.    There is a missing packet VLAN in the VSM configuration.
C.    VSM has no network connection to vCenter.
D.    The VSM extension key is not installed on vCenter.
E.    The vCenter extension key is not installed on VSM.

Answer: D

QUESTION 240
Refer to the exhibit. Which option is valid for connecting the fabric interconnect to the I/O module?


A.    A, B, C, and D are valid.
B.    A and B are valid.
C.    A, B, and D are valid.
D.    Only A is valid.

Answer: B


Braindump2go Guarantee:
Pass-Certification 350-080 offers absolute risk free investment opportunity, values your timr and money! Braindump2go latest 350-080 Real Exam Dumps – Your success in 350-080 Exam is certain! Your belief in our 350-080 Exam Dumps is further strengthened with 100% Money Back Promise from Braindump2go!

FREE DOWNLOAD: NEW UPDATED 350-080 PDF Dumps & 350-080 VCE Dumps from Braindump2go: http://www.braindump2go.com/350-080.html (394 Q&A)